| Model | Gentier96E | Gentier96S | Gentier96R | Gentier96C | |
| Thermal block | |||||
| Sample capacity(wells) | 96 | ||||
| Reaction volume | 0-100ul | ||||
| Consumable | 0.2ml 96-WELL plates(unskirt)0.2ml 8-strip tubes,0.2ml PCR single tube(Optical flat cap. Clear,frosted,white tube) | ||||
| Temperature range |
0℃-100℃ |
||||
| Heating/cooling system | Peltier | ||||
| Max heating rate | 6.1℃/sec | ||||
| Average heating rate | 4.5℃/sec | ||||
| Max cooling rate | 5.0℃/sec | ||||
| Average cooling rate | 2.8℃/sec | ||||
| Temperature accuracy | ±0.1℃ | ||||
| Temperature uniformity | ±0.1℃ | ||||
| Gradient range | 1℃-40℃ | N/A | 1℃-40℃ | N/A | |
| Gradient block | 12row | 12row | 8row | ||
| Special temperature protocol | Gradient PCR, Long PCR, Touch Down PCR |
Long PCR, Touch Down PCR |
Gradient PCR, Long PCR, Touch Down PCR | Long PCR, Touch Down PCR | |
| Heat Lid | |||||
| Temperature range | Room temperature-110℃ | ||||
| Optical system | |||||
| Excitation Source | 6LEDs | 4LEDs | |||
| Detector | Photodiode | ||||
| Detection position | Excitation and scan at top | ||||
| Detection method | 6 channels scanning at the same time, no edge effect | ||||
| Detection time | 7 seconds for 96 wells for all channels | ||||
| Range of excitation/emission wavelengths(nm) |
1. 465/510(FAM,SYBR Green I,SYTO9,Eva Green, LC Green) 2. 527/563(HEX,VIC,TET,JOE) 3. 580/616(ROX,Texas Red) 4. 632/664(Cy5) 5.680/730(Alexa Fluor680) 6.465/616(FRET) |
1. 465/510(FAM,SYBR Green I,SYTO9,Eva Green, LC Green) 2. 527/563(HEX,VIC,TET,JOE) 3. 580/616(ROX,Texas Red) 4. 632/664(Cy5) |
|||
| Probe Taqman Probe,Molecular beacons probe, scorpion probe,FRET | Taqman Probe,Molecular beacons probe, scorpion probe, | ||||
| Multiplexing | Up to 6 targets | Up to 4 targets | |||
| Fluorescence Linearity | r≥0.990 | ||||
| Fluorescence Dynamic Range | Adjustable | ||||
| Performance | |||||
| Sample Linearity | /r/≥0.999 | ||||
| Sample repeatability | Ct value CV≤0.5% | ||||
| Sample dynamic Range | 1-1010 | ||||
| Software Functions | |||||
| Data Analysis Modes | Qualitative analysis, Absolute quantification, Relative quantification, Genotyping analysis, Endpoint analysis, Melt curve analysis, High Resolution Melting | ||||
| Control Modes |
10.4touch screen PC direct control WLAN control(one PC can control max 10 unit, and device can be controlled by any PC in the WLAN) |
||||
| Sample Drawer | Touch Screen commend | ||||
| Data Storage | Upload and download through USB disk, 1000 results can be stored in machine | ||||
| Power failure protection | Automaticly start running experiments after power supply, no need wait PC software | ||||
| Customize Report | Templetes reserved, report can customized | ||||
| Administration Management | Administratior can set functions limits for users | ||||
| Transport Locker | Automaticly detect transport locker | ||||
| Fault Management | Fault report and analysis,solution instruction | ||||
| LIS connection | CSV,Excel,TXT format data output, open port for LIS connection | ||||
| Others | |||||
| PC operating system | Win7, Win 10 | ||||
| Communication Port | 1 ethernet and 3 USB | ||||
| Foot pprint(WxDxH) | 355mmX480mmX485mm | ||||
| Weight | 30kg | ||||
| Power usage | AC100 to 125V/200to 240V(50/60HZ) | ||||
| Power consumption | 900VA | ||||
| Work environment | Temperature:10℃~30℃ Humidity:20%~85% | ||||